Electrochemical evaluation of stainless steel welded tubes

Main Article Content

Javier E. Rodríguez-Yáñez
Ericka Saborío-Leiva
Daniel Mora-Montoya

Abstract

The recovery of 316L steel capillaries used in neutral geothermal wells orbital welding by weld is evaluated from the point of view of its resistance to corrosion in the conditions of use, through basic electrochemical techniques.

In the pre-treatment is more convenient than carrying out a chemical pickling prior to welding for 5 minutes. While subsequent to the application of welding heat treatment of stress reduction is not justified from the standpoint of corrosion resistance.

There is also the comparison of capillaries capillary soldiers regarding new and used soldier’s capillaries having an intermediate behavior between the two.

Article Details

How to Cite
Rodríguez-Yáñez, J. E., Saborío-Leiva, E., & Mora-Montoya, D. (2014). Electrochemical evaluation of stainless steel welded tubes. Tecnología En Marcha Journal, 27(1), pág. 57–65. https://doi.org/10.18845/tm.v27i1.1696
Section